Description
This reagent is routinely tested by flow cytometric analysis. Other applications were tested at BD Biosciences Pharmingen during reagent development only or reported in the literature.
Format
- FormatAPC-Cy™7
- Excitation SourceRed 633 nm
- Excitation Max650nm
- Emission Max785nm
APC-Cy™7 is a tandem fluorochrome that combines APC and a cyanine dye (Cy7). Special precautions must be taken with APC-Cy7 conjugates, and cells stained with them, to protect the fluorochrome from long-term exposure to light. Some APC-Cy7 conjugates show changes in their emission spectra with prolonged exposure to paraformaldehyde. Fixed cells should be analyzed within 4 hours of fixation in paraformaldehyde or transferred to a paraformaldehyde-free buffer for overnight storage. Due to nearly identical excitation and emission properties but different spillover characteristics, APC-Cy7 and APC-H7 cannot be used simultaneously.
Other Formats→
- AKP
- APC
- APC-R700
- BB515
- BUV395
- BUV496
- BUV563
- BUV615
- BUV661
- BUV737
- BUV805
- BV421
- BV480
- BV510
- BV605
- BV650
- BV711
- BV786
- FITC
- HRP
- PE
- PE-CF594
- PE-Cy™5
- PE-Cy™7
- PerCP
- PerCP-Cy™5.5
- V450
- V500
Suggested Companion Products
Stain Buffer (FBS) RUO 500mLCat No: 554656
Stain Buffer (BSA) RUO 500mLCat No: 554657
Biotin Rat Anti-Mouse CD8a 53-6.7RUO 0.1mgCat No: 553028
APC Rat Anti-Mouse CD4 RM4-5 (also known as RM4.5)RUO 0.1mgCat No: 553051
Biotin Rat Anti-Mouse CD8a 53-6.7RUO 0.5mgCat No: 553029
APC Hamster Anti-Mouse CD3e 145-2C11RUO 0.1mgCat No: 553066
Biotin Rat Anti-Mouse CD45R/B220 RA3-6B2RUO 0.1mgCat No: 553085
Biotin Rat Anti-Mouse CD45R/B220 RA3-6B2RUO 0.5mgCat No: 553086
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | SpectrumViewer | Download TDS | Download MSDS |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light.Do not freeze.Streptavidin was conjugated with dye under optimum conditions, and unconjugated Streptavidin and free dye were removed
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- APC-Cy7 is a tandem fluorochrome composed of Allophycocyanin (APC), which is excited by laser lines between 595 and 647 nm and serves as an energy donor, coupled to the cyanine dye Cy7™, which acts as an energy acceptor and fluoresces at 780 nm.BD Biosciences Pharmingen has maximized the fluorochrome energy transfer in APC-Cy7, thus maximizing its fluorescence emission intensity, minimizing residual emission from APC, and minimizing required electronic compensation in multilaser-laser flow cytometry systems. Note:Although every effort is made to minimize the lot-to-lot variation in residual emission from APC, it is strongly recommended that every lot be tested for differences in the amount of compensation required and that individual compensation controls are run for each APC-Cy7 conjugate.
- APC-Cy7 tandem fluorochrome emission is collected in a detector for fluorescence wavelengths of 750 nm and higher.
- Please observe the following precautions:Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
- Warning: Some APC-Cy7 and PE-Cy7 conjugates show changes in their emission spectrum with prolonged exposure to formaldehyde.If you are unable to analyze fixed samples within four hours, we recommend that you use BD™ Stabilizing Fixative (Cat. No. 338036).
- Cy is a trademark of GE Healthcare.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.