Description
Streptavidin is a non-glycosylated protein that is prepared chromatographically from the bacterium Streptomyces avidinii. Streptavidin homotetramers have a particularly high, non-covalent binding affinity for biotin. When conjugated with fluorochromes, streptavidin has been widely used with biotin-conjugated antibodies and other biotinylated specific-binding molecules (eg, recombinant proteins and lectins) to stain cells and tissues for subsequent multiparameter analysis by flow cytometry, fluorescence microscopy and imaging. Likewise, when conjugated with an enzyme (eg, Horseradish Peroxidase or Alkaline Phosphatase) and coupled with a colorimetric or luminescent substrate development system, streptavidin has found widespread use along with biotinylated antibodies in a number of applications including Western blot, ELISA, BD™ ELISPOT, immunocytochemistry and immunohistochemistry.
Streptavidin is conjugated to BD Horizon PE-CF594, which has been developed exclusively by BD Biosciences as a better alternative to PE-Texas Red®. PE-CF594 excites and emits at similar wavelengths to PE-Texas Red® yet exhibits improved brightness and spectral characteristics. Due to PE having maximal absorption peaks at 496 nm and 564 nm, PE-CF594 can be excited by the blue (488-nm), green (532-nm) and yellow-green (561-nm) lasers and can be detected with the same filter set as PE-Texas Red® (eg 610/20-nm filter).
Format
- FormatPE-CF594
- Excitation SourceBlue 488 nm,Green 532 nm,Yellow/Green 561 nm
- Excitation Max496nm
- Emission Max612nm
BD Horizon™ PE-CF594 is a tandem conjugate, developed exclusively by BD Biosciences, that combines PE and CF594. PE-CF594 is a brighter alternative to PE-Texas Red®, with improved spectral characteristics. PE-CF594 reagents exhibit very consistent spillover values lot to lot, making them an ideal choice for the PE-Texas Red® detector (610/20 nm).
Other Formats→
- AKP
- APC
- APC-Cy™7
- APC-R700
- BB515
- BUV395
- BUV496
- BUV563
- BUV615
- BUV661
- BUV737
- BUV805
- BV421
- BV480
- BV510
- BV605
- BV650
- BV711
- BV786
- FITC
- HRP
- PE
- PE-Cy™5
- PE-Cy™7
- PerCP
- PerCP-Cy™5.5
- V450
- V500
Suggested Companion Products
Biotin Rat Anti-Mouse CD45R/B220 RA3-6B2RUO 0.5mgCat No: 553086
Stain Buffer (BSA) RUO 500mLCat No: 554657
PE-CF594 Streptavidin RUO 25mgCat No: 562318
Stain Buffer (FBS) RUO 500mLCat No: 554656
PE-Texas Red Streptavidin RUO 0.1mgCat No: 551487
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | SpectrumViewer | Download TDS | Regulatory Document Website |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light.Do not freeze.Streptavidin was conjugated with dye under optimum conditions, and unconjugated Streptavidin and free dye were removed
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- When excited by the yellow-green (561-nm) laser, the fluorescence may be brighter than when excited by the blue (488-nm) laser.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using multi-laser cytometers, which may directly excite both PE and CF™594.
- Please observe the following precautions:Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
- CF™ is a trademark of Biotium, Inc.
- This product is provided under an Agreement between BIOTIUM and BD Biosciences. The manufacture, use, sale, offer for sale, or import of this product is subject to one or more patents or pending applications owned or licensed by Biotium, Inc.This product, and only in the amount purchased by buyer, may be used solely for buyer’s own internal research, in a manner consistent with the accompanying product literature.No other right to use, sell or otherwise transfer (a) this product, or (b) its components is hereby granted expressly, by implication or by estoppel.This product is for research use only.Diagnostic uses require a separate license from Biotium, Inc. For information on purchasing a license to this product including for purposes other than research, contact Biotium, Inc., 3159 Corporate Place, Hayward, CA 94545, Tel: (510) 265-1027.Fax: (510) 265-1352. Email: btinfo@biotium.com.
- Texas Red is a registered trademark of Molecular Probes, Inc., Eugene, OR.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.