Description
SAv-PE-Cy7 is a useful second-step reagent for the indirect immunofluorescent staining of cells in combination with biotinylated primary antibodies for flow cytometric analysis.
Format
- FormatPE-Cy™7
- Excitation SourceBlue 488 nm,Green 532 nm,Yellow/Green 561 nm
- Excitation Max496nm
- Emission Max785nm
PE-Cy™7 is a tandem fluorochrome that combines PE and a cyanine dye. PE-Cy7 conjugated reagents are as bright as PE conjugates. PE-Cy7 is particularly sensitive to photo-induced degradation, resulting in loss of fluorescence and changes in fluorescence spillover. Extreme caution must be taken to avoid light exposure and prolonged exposure to paraformaldehyde fixative. Fixed cells should be analyzed within 4 hours of fixation in paraformaldehyde or transferred to a paraformaldehyde-free buffer for overnight storage.
Other Formats→
- AKP
- APC
- APC-Cy™7
- APC-R700
- BB515
- BUV395
- BUV496
- BUV563
- BUV615
- BUV661
- BUV737
- BUV805
- BV421
- BV510
- BV605
- BV650
- BV711
- BV786
- FITC
- HRP
- PE
- PE-CF594
- PE-Cy™5
- PerCP
- PerCP-Cy™5.5
- V450
- V500
Suggested Companion Products
Stain Buffer (BSA) RUO 500mLCat No: 554657
Stain Buffer (FBS) RUO 500mLCat No: 554656
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | SpectrumViewer | Download TDS | Download MSDS |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light.Do not freeze.Streptavidin was conjugated with dye under optimum conditions, and unconjugated Streptavidin and free dye were removed
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- PE-Cy7 is a tandem fluorochrome composed of R-phycoerythrin (PE), which is excited by 488-nm light and serves as an energy donor, coupled to the cyanine dye Cy7, which acts as an energy acceptor and fluoresces maximally at 780 nm. PE-Cy7 tandem fluorochrome emission is collected in a detector for fluorescence wavelengths of 750 nm and higher. Although every effort is made to minimize the lot-to-lot variation in the efficiency of the fluorochrome energy transfer, differences in the residual emission from PE may be observed.Therefore, we recommend that individual compensation controls be performed for every PE-Cy7 conjugate.PE-Cy7 is optimized for use with a single argon ion laser emitting 488-nm light, and there is no significant overlap between PE-Cy7 and FITC emission spectra.When using dual-laser cytometers, which may directly excite both PE and Cy7, we recommend the use of cross-beam compensation during data acquisition or software compensation during data analysis.
- Please observe the following precautions:Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
- Warning: Some APC-Cy7 and PE-Cy7 conjugates show changes in their emission spectrum with prolonged exposure to formaldehyde.If you are unable to analyze fixed samples within four hours, we recommend that you use BD™ Stabilizing Fixative (Cat. No. 338036).
- Cy is a trademark of GE Healthcare.
- Please refer to http://regdocs.bd.com to access safety data sheets (SDS).
- Please refer to www.bdbiosciences.com/us/s/resources for technical protocols.
Note: Although every effort is made to minimize the lot-to-lot variation in residual emission from PE, it is strongly recommended that every lot be tested for differences in the amount of compensation required and that individual compensation controls are run for each PE-Cy7 conjugate.