Description
The G53-238 antibody reacts specifically with rat IgM monomers and pentamers. It does not react with other Ig isotypes. G53-238 antibody has not been shown to stimulate B-cell proliferation.
Format
- FormatFITC
- Excitation SourceBlue 488 nm
- Excitation Max494nm
- Emission Max520nm
FITC, fluorescein isothiocyanate, is a fluorochrome with a molecular weight of 389 Da. FITC is sensitive to pH changes and photobleaching. Due to nearly identical excitation and emission properties but different spillover characteristics, FITC and Alexa Fluor® 488 cannot be used simultaneously. FITC is relatively dim and should be reserved for highly expressed markers whenever possible.
Other Formats→
- BB700
- BUV395
- BUV615
- BUV661
- BV421
- BV480
- BV510
- BV605
- BV650
- BV711
- BV750
- BV786
- Biotin
- PE
- Purified
Suggested Companion Products
FITC Mouse IgG1, κ Isotype Control RUO 0.1mgCat No: 554679
Resources & Tools | ||||||
---|---|---|---|---|---|---|
Spectrum Viewer | Panel Designer | SpectrumViewer | Download TDS | Regulatory Document Website |
Preparation and Storage
The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.The antibody was conjugated with FITC under optimum conditions, and unreacted FITC was removed.Store undiluted at 4°C and protected from prolonged exposure to light.Do not freeze.
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- Please refer to www.bdbiosciences.com/pharmingen/protocols for technical protocols.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
FITC-conjugated G53-238 mAb may be used as a primary or secondary reagent in immunofluorescent staining. For flow cytometric detection ofintracytoplasmic IgM, please refer to the following protocol.
IMMUNOFLUORESCENT STAINING OF INTRACELLULAR IMMUNOGLOBULIN (Ig) PROTOCOL
1. Prepare a single-cell suspension and determine cell number.
2. Suspend cells in staining buffer (PBS + 2% FBS + 0.1% Sodium Azide) at 2 x 10e7 cells/ml and transfer to U-bottom microwell plates in 50 µl/well for immunofluorescent staining.
Note: The BD Pharmingen. Stain Buffer with FBS (Cat. No. 554656) is effective for use as a staining buffer in this protocol.
3. Block Fcγ receptors by adding Rat BD Fc Block., purified anti-rat CD32 mAb D35-485 (Cat. No. 550270/550271) in 50 µl of staining buffer to each well.
4. Incubate 5 minutes on ice.
5. Add 200 µl of staining buffer/well and resuspend cells. Centrifuge at 250 x g for 5 minutes and aspirate supernatant.
6. Block surface Ig with purified G53-238 mAb (Cat. No. 553885) by adding 1.0 µg per sample in 50 µl of staining buffer/well.
Note: Surface markers may be stained during this step as described in the "Immunofluorescent Staining of Mouse and Rat Leukocytes for Flow Cytometry" in the Technical Protocols section of our website at http://www.bdbiosciences.com/pharmingen/protocols/Mouse_and_Rat_Leukocytes.shtml
7. Incubate 15 minutes on ice.
8. Wash 2x as described in Step 5.
9. Resuspend cells in 100 µl of BD Cytofix/Cytoperm. intracellular staining buffer (BD Cytofix/Cytoperm. Kit, Cat. No. 554714) per well.
10. Incubate 30 minutes at room temperature.
11. Wash 2x with 200 µl of 1 x Perm/Wash buffer (provided in the BD Cytofix/Cytoperm Kit) per well. Centrifuge at 250 x g for 5 minutes and aspirate supernatant between washes.
12. Stain intracellular Ig by adding ≤ 1 µg of FITC-conjugated G53-238 mAb in 50 µl of 1 x Perm/Wash buffer/well.
Note: Other antibodies recommended for staining of intracellular markers may be added during this step as described in Step 12.
13. Incubate for 30 minutes at room temperature.
14. Wash 2x as described in Step 11.
15. Resuspend and transfer samples in 100 µl of staining buffer to tubes appropriate for analysis with a flow cytometer. Bring volume in each tube to 400 µl with staining buffer.
16. Analyze samples on a flow cytometer.