The MOPC-173 antibody has unknown specificity.The transplantable plasmacytoma MOPC-173 was induced by intraperitoneal injection of mineral oils into BALB/c mice.In the absence of antigen-specific binding, this immunoglobulin may bind non-specifically to Fc receptors.
Format
- FormatPerCP-Cy™5.5
- Excitation SourceBlue 488 nm
- Excitation Max482nm
- Emission Max678nm
PerCP-Cy™5.5 is a tandem conjugate that combines PerCP with a cyanine dye. PerCP-Cy5.5 is not subject to photobeaching like PerCP and can be used with stream-in-air flow cytometers. It has less Fc receptor–mediated nonspecific staining than PE-Cy5. Additionally, the PerCP-Cy5.5 tandem conjugate is not as susceptible to fixative or light instability compared to APC-Cy7 and PE-Cy7.
Other Formats→
- Alexa Fluor® 488
- Alexa Fluor® 647
- Alexa Fluor® 700
- BV421
- BV510
- BV650
- BV786
- PE
- PE-CF594
- PE-Cy™7
- Purified
- V450
Suggested Companion Products
Stain Buffer (FBS) RUO 500mLCat No: 554656
Stain Buffer (BSA) RUO 500mLCat No: 554657
PerCP-Cy™5.5 Mouse IgG2a, κ Isotype Control RUO 50TestsCat No: 558020
Resources & Tools | ||||||
---|---|---|---|---|---|---|
SpectrumViewer | Download TDS | Regulatory Document Website |
Preparation and Storage
Store undiluted at 4°C and protected from prolonged exposure to light.Do not freeze.The monoclonal antibody was purified from tissue culture supernatant or ascites by affinity chromatography.The antibody was conjugated with PerCP-Cy5.5 under optimum conditions, and unconjugated antibody and free PerCP-Cy5.5 were removed.Storage of PerCP-Cy5.5 conjugates in unoptimized diluent is not recommended and may result in loss of signal intensity.
Product Notices
- Since applications vary, each investigator should titrate the reagent to obtain optimal results.
- An isotype control should be used at the same concentration as the antibody of interest.
- Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
- Please observe the following precautions:Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
- PerCP-Cy5.5–labelled antibodies can be used with FITC- and R-PE–labelled reagents in single-laser flow cytometers with no significant spectral overlap of PerCP-Cy5.5, FITC, and R-PE fluorescence.
- PerCP-Cy5.5 is optimized for use with a single argon ion laser emitting 488-nm light. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using dual-laser cytometers, which may directly excite both PerCP and Cy5.5™. We recommend the use of cross-beam compensation during data acquisition or software compensation during data analysis.
- For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
- Cy is a trademark of GE Healthcare.
- Please refer to www.bdbiosciences.com/pharmingen/protocols for technical protocols.