4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:主营:医疗设备、医疗耗材、实验仪器、抗体、试剂、诊断等产品
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > peptide > BD Biosciences/Human MSC Analysis Kit/50Tests/562245
商品详细BD Biosciences/Human MSC Analysis Kit/50Tests/562245
BD Biosciences/Human MSC Analysis Kit/50Tests/562245
BD Biosciences/Human MSC Analysis Kit/50Tests/562245
商品编号: 562245
品牌: bdbiosciences
市场价: ¥27930.00
美元价: 15960.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Product DetailsRecommended AssayReferences

Description

Human multipotent mesenchymal stromal cells (MSCs), also referred to as mesenchymal stem cells, are a rare population of adult stem cells that can be isolated from a variety of tissues.MSCs that have been isolated from bone marrow and subsequently cultured can differentiate to a variety of cell types, most notably adipocytes, osteocytes and chondrocytes.MSCs also have immunomodulatory effects in vivo and in vitro.In 2006, the International Society for Cellular Therapy (ISCT) proposed a cell surface marker panel for the minimal identification of human MSCs derived from bone marrow.Under this recommendation MSCs should be positive for CD73, CD90, and CD105, but be negative for CD34, CD45, CD11b or CD14, CD19 or CD79α, and HLA-DR.MSCs are also known to express numerous cell surface markers such as CD44, CD29, CD200, CD166, CD146 and CD271.In this kit we include the panel that was proposed by the ISCT.In addition, we designed this kit to be modular so that additional markers could be "dropped-in".Specifically, the MSC positive cocktail (FITC CD90, PerCP-Cy™5.5 CD105 and APC CD73) leaves the PE channel open to use in combination with the supplied negative MSC cocktail (PE CD45, PE CD34, PE CD11b, PE CD19 and PE HLA-DR), the included PE CD44 antibody conjugate, or a variety of other commercially available PE antibody conjugates.Multi color analysis minimizes cell numbers required for an assay and antibody cocktails facilitate a streamlined staining protocol to analyze multiple samples.Individual positive markers are included for compensation set-up.

Kit Components

ComponentDescriptionSizeVol. Per TestStorage Buffer

51-9007661PE hMSC Negative Cocktail50 Test20 µlAqueous buffered solution containing

BSA and ≤0.09% sodium azide

51-9007662PE hMSC Isotype Control Negative Cocktail50 Test20 µlAqueous buffered solution containing

BSA and ≤0.09% sodium azide

51-9007663hMSC Positive Cocktail50 Test20 µlAqueous buffered solution containing

BSA and ≤0.09% sodium azide

51-9007664hMSC Isotype Control Positive Cocktail50 Test20 µlAqueous buffered solution containing

BSA and ≤0.09% sodium azide

51-9007657FITC Mouse Anti-Human CD9050 Test5 µlAqueous buffered solution containing

BSA and ≤0.09% sodium azide

51-9007656PE Mouse Anti-Human CD44100 Test5 µlAqueous buffered solution containing BSA,

protein stabilizer, and ≤0.09% sodium azide

51-9007655PE Mouse IgG2b, k Isotype Control50 Test5 µlAqueous buffered solution containing

BSA and ≤0.09% sodium azide

51-9007649APC Mouse Anti-Human CD7350 Test5 µlAqueous buffered solution containing

BSA and ≤0.09% sodium azide

51-9007648PerCP-Cy™5.5 Mouse Anti-Human CD10550 Test5 µlAqueous buffered solution containing

(Endoglin)BSA and ≤0.09% sodium azide

Description of Kit Components

VialContentsPurpose

hMSC Positive CocktailCD90 FITC (Clone: 5E10)Cocktail to positively identify hMSCs

CD105 PerCP-Cy5.5 (Clone: 266)

CD73 APC (Clone: AD2)

hMSC Positive Isotype Control CocktailmIgG1, κ FITC (Clone: X40)Corresponding Isotype Control for hMSC PositivemIgG1, κ PerCP-Cy5.5 (Clone: X40)Cocktail

mIgG1, κ APC (Clone: X40)

PE hMSC Negative CocktailCD34 PE (Clone:581)Cocktail to identify potential contaminants

CD11b PE (Clone: ICRF44)

CD19 PE (Clone: HIB19)

CD45 PE (Clone: HI30)

HLA-DR PE (Clone: G46-6)

PE hMSC Negative Isotype Control CocktailmIgG1, κ PE (Clone: X40)Corresponding isotype control for PE hMSC

mIgG2a, κ PE (Clone:G155-178)Negative Cocktail

FITC Mouse Anti-human CD90CD90 FITC (Clone: 5E10)Compensation control

PE Mouse Anti-Human CD44CD44 PE (Clone: G44-26)Compensation control/MSC positive drop-in

PerCP-Cy™5.5 Mouse Anti-Human CD105CD105 PerCP-Cy™5.5 (Clone: 266)Compensation control

APC Mouse Anti-Human CD73CD73 APC (Clone:AD2)Compensation control

PE Mouse IgG2b, κ Isotype ControlmIgG2b, κ (Clone: 27-35)Corresponding Isotype Control for PE Mouse

Anti-Human CD44, when used as a drop in

Suggested Companion Products

Stain Buffer (FBS) RUO 500mLCat No: 554656

Accutase™ Cell Detachment Solution RUO 100mLCat No: 561527

Preparation and Storage

Store undiluted at 4°C and protected from prolonged exposure to light.Do not freeze.The antibody was conjugated with R-PE under optimum conditions, and unconjugated antibody and free PE were removed.The antibody was conjugated with PerCP-Cy5.5 under optimum conditions, and unconjugated antibody and free PerCP-Cy5.5 were removed.Storage of PerCP-Cy5.5 conjugates in unoptimized diluent is not recommended and may result in loss of signal intensity.The antibody was conjugated with FITC under optimum conditions, and unreacted FITC was removed.The antibody was conjugated to APC under optimum conditions, and unconjugated antibody and free APC were removed.

Product Notices

  1. Accutase is a registered trademark of Innovative Cell Technologies, Inc.
  2. Please observe the following precautions:Absorption of visible light can significantly alter the energy transfer occurring in any tandem fluorochrome conjugate; therefore, we recommend that special precautions be taken (such as wrapping vials, tubes, or racks in aluminum foil) to prevent exposure of conjugated reagents, including cells stained with those reagents, to room illumination.
  3. This APC-conjugated reagent can be used in any flow cytometer equipped with a dye, HeNe, or red diode laser.
  4. PerCP-Cy5.5 is optimized for use with a single argon ion laser emitting 488-nm light. Because of the broad absorption spectrum of the tandem fluorochrome, extra care must be taken when using dual-laser cytometers, which may directly excite both PerCP and Cy5.5™. We recommend the use of cross-beam compensation during data acquisition or software compensation during data analysis.
  5. PerCP-Cy5.5–labelled antibodies can be used with FITC- and R-PE–labelled reagents in single-laser flow cytometers with no significant spectral overlap of PerCP-Cy5.5, FITC, and R-PE fluorescence.
  6. Cy is a trademark of Amersham Biosciences Limited. This conjugated product is sold under license to the following patents: US Patent Nos. 5,486,616; 5,569,587; 5,569,766; 5,627,027.
  7. This product is subject to proprietary rights of Amersham Biosciences Corp. and Carnegie Mellon University and made and sold under license from Amersham Biosciences Corp. This product is licensed for sale only for research. It is not licensed for any other use. If you require a commercial license to use this product and do not have one return this material, unopened to BD Biosciences, 10975 Torreyana Rd, San Diego, CA 92121 and any money paid for the material will be refunded.
  8. Source of all serum proteins is from USDA inspected abattoirs located in the United States.
  9. Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before discarding to avoid accumulation of potentially explosive deposits in plumbing.
  10. For fluorochrome spectra and suitable instrument settings, please refer to our Multicolor Flow Cytometry web page at www.bdbiosciences.com/colors.
  11. Please refer to www.bdbiosciences.com/pharmingen/protocols for technical protocols.

  1. Bühring HJ, Battula VL, Treml S, Schewe B, Kanz L, Vogel W. Novel markers for the prospective isolation of human MSC. Ann N Y Acad Sci. 2007; 1106:262-271.View reference

  2. Dominici M, Le Blanc K, Mueller I, et. al. Minimal criteria for defining multipotent mesenchymal stromal cells. The International Society for Cellular Therapy position statement. Cytotherapy. 2006; 8(4):315-317.View reference

  3. Horwitz EM, Le Blanc K, Dominici M, et. al. Clarification of the nomenclature for MSC: The International Society for Cellular Therapy position statement. Cytotherapy. 2005; 7(5):393-395.View reference

  4. Kern S, Eichler H, Stoeve J, Klüter H, Bieback K. Comparative analysis of mesenchymal stem cells from bone marrow, umbilical cord blood, or adipose tissue. Stem Cells. 2006; 24(5):1294-1301.View reference

  5. Sánchez L, Gutierrez-Aranda I, Ligero G, et al. Enrichment of Human ESC-Derived Multipotent Mesenchymal Stem Cells with Immunosuppressive and Anti-Inflammatory Properties Capable to Protect Against Experimental Inflammatory Bowel Disease. Stem Cells. 2010; 29(2):251-262.View reference

品牌介绍
BD是世界上最大的生产和销售医疗设备、医疗系统和试剂的医疗技术公司之一。致力于提高全世界人类的健康水平。BD专注于改进药物治疗,提高传染性疾病诊断的质量和速度,推进新型药物和疫苗的研究与发现。BD公司具有强大的研发能力和世界上最棘手的多种疾病进行斗争的能力。公司于1897年在纽约成立,总部位于美国新泽西州的富兰克林湖,业务遍及全球。公司的业务可分为BD医疗、BD诊断、BD生物科学三大类,生产销售包括医用耗材、实验室仪器、抗体、试剂、诊断等产品。公司的服务对象包括医疗机构,生命科学研究所,临床实验室,工业单位和普通大众。BD has state-of-the-art facilities around the globe that provide an environment that enables our highly talented workforce to be the best at their professions. We hire associates who have a passion and commitment to advancing the world of health. We are always seeking great people to join our company on its journey to greatness.BDRat Granulocytes Pure RP-1  500ug550002BDMs Ig Kpa Lgt Chain FITC 187.1  500ug550007BDICC Fixation Buffer 100mL550011BDMs CD210 NALE 1B1.3a 500ug550019BDMs CD51 Pure RMV-7 100ug550026BDMs CD5 APC 53-7.3 100ug550037BDHu CD62E PE-Cy5 68-5H11 100Tst550041BDHu CD95 Pure EOS9.1  100ug550052BDHam IgG2 Kpa ItCl FITC B81-3 250ug550057BDMs Crry/p65 Pure 1F2 100ug550059BDMs IL-4 Recom Protein 10ug550068BDMs IL-2 Recom Protein 20ug550070BDHu IL-6 Recom Protein 10ug550072BDHu MIP-1 Bta PE D21-1351 100ug550082BDMs IgG1 PE A85-1 100ug550084BDHam IgG2 Kpa ItCl PE B81-3 100ug550086BDHu CD142 Pure HTF-1 100ug550254BDHu CD1d PE CD1d42 100Tst550256BDHu CD73 PE AD2 100Tst550258BDHu CD103 FITC Ber-ACT8 100Tst550260BDMs CD11c APC HL3 100ug550268BDMs CD72b/c Aloatg PE JY/93 100ug550270BDRat CD32 Pure D34-485 500ug550272BDRat CD32 NALE D34-485 500ug550274BDMs CD3e IHC Pure 145-2C11 1mL550277BDMs CD4 IHC Pure H129.19 1mL550280BDMs CD8a IHC Pure 53-6.7 1mL
联络我们
服务热线:4000-520-616
(限工作日9:00-18:00)
QQ :1570468124
手机:18915418616