4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:主营:医疗设备、医疗耗材、实验仪器、抗体、试剂、诊断等产品
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > peptide > BD Biosciences/FMC7 FITC/CD23 PE/CD19 PerCP-Cy™5.5/331359
商品详细BD Biosciences/FMC7 FITC/CD23 PE/CD19 PerCP-Cy™5.5/331359
BD Biosciences/FMC7 FITC/CD23 PE/CD19 PerCP-Cy™5.5/331359
BD Biosciences/FMC7 FITC/CD23 PE/CD19 PerCP-Cy™5.5/331359
商品编号: 331359
品牌: bdbiosciences
市场价: ¥0.00
美元价: 0.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Product DetailsRecommended AssayReferences

Description

BD Oncomark™ FMC7 FITC/CD23 PE/CD19 PerCP-Cy5.5 is intended for in vitro flow cytometric immunophenotyping of normal and abnormal subsets of B lymphocytes. The reagents detect expression of the FMC7 and CD23 antigens on normal and abnormal B cells. The FMC7 antigen is present in a subset of normal B lymphocytes, but is weak or undetectable in chronic lymphocytic leukemia (CLL). The CD23 antigen is not usually present in mantle cell lymphoma but might be present in other B-cell neoplasms such as B-cell CLL and small lymphocytic lymphomas. FMC7/CD23/CD19 assays are used in the diagnosis of hematologic disorders.

Contents

SpecificityCloneFormatIsotypeEntrez Gene ID
FMC7FMC7FITCIgM, κ931
CD23EBVCS-5 (also known as EBVCS 5)PEIgG1, κ2208
CD19SJ25C1 (also known as SJ25-C1)PerCP-Cy™5.5IgG1, κ930
Preparation and Storage

The antibody reagent is stable until the expiration date shown on the label when stored at 2° to 8°C. Do not use after the expiration date. Do not freeze the reagent or expose it to direct light during storage or incubation with cells. Keep the outside of the reagent vial dry.

Do not use the reagent if you observe any change in appearance. Precipitation or discoloration indicates instability or deterioration.

  1. Protection of Laboratory Workers from Occupationally Acquired Infections–Second Edition; Approved Guideline. Villanova, PA: National Committee for Clinical Laboratory Standards; 2001. NCCLS document M29-A2.

  2. Bloem AC, Chand MA, Dollekamp I, Rijkers GT. Functional properties of human B cell subpopulations defined by monoclonal antibodies HB4 and FMC7. J Immunol. 1988;140:768-773.

  3. Brooks DA, Beckman IGR, Bradley J, McNamara PJ, Thomas ME, Zola H. Human lymphocyte markers defined by antibodies derived from somatic cell hybrids. IV. A monoclonal antibody reacting specifically with a subpopulation of human B lymphocytes. J Immunol. 1981;126:1373-1377.

  4. Capron M, Jouault T, Prin L, et al. Functional study of a monoclonal antibody to IgE Fc receptor (FcεR2) of eosinophils, platelets, and macrophages. J Exp Med. 1986;164:72-89.

  5. Centers for Disease Control. Update: universal precautions for prevention of transmission of human immunodeficiency virus, hepatitis B virus, and other bloodborne pathogens in health-care settings. MMWR. 1988;37:377-388.

  6. DiGiuseppe JA, Borowitz MJ. Clinical utility of flow cytometry in the chronic lymphoid leukemias. Semin Oncol. 1998;25:6-10.

  7. Geisler CH, Larsen JK, E HN, et al. Prognostic importance of flow cytometric immunophenotyping of 540 consecutive patients with B-cell chronic lymphocytic leukemia. Blood. 1991;78:1795-1802.

  8. Gordon J, Rowe M, Walker L, Guy G. Ligation of the CD23,p45 (Blast-2, EBVCS) antigen triggers the cell-cycle progression of activated B lymphocytes. Eur J Immunol. 1986;16:1075-1080.

  9. Gordon J, Webb A, Walker L, Guy G, Rowe M. Evidence of an association between CD23 and the receptor for a low molecular weight B-cell growth factor. Eur J Immunol. 1986;16:1627.

  10. Hassan IB, Hagberg H, Sundström C. Immunophenotype of hairy-cell leukemia. Eur J Haematol. 1990;45:172-176.

  11. Hoffkes HG, Schmidtke G, Uppenkamp M, Schmucker U. Multiparametric immunophenotyping of B cells in peripheral blood of healthy adults by flow cytometry. Clin Diagn Lab Immunol. 1996;3:30-36.

  12. Huh YO, Pugh WC, Kanjarjian HM, et al. Detection of subgroups of chronic B-cell leukemias by FMC7 monoclonal antibody. Am J Clin Pathol. 1994;101:283-289.

  13. Hübl W, Iturraspe J, Braylan RC. FMC7 antigen expression on normal and malignant B-cells can be predicted by expression of CD20. Cytometry. 1998;34:71-74.

  14. Jackson AL, Warner NL. Preparation, staining, and analysis by flow cytometry of peripheral blood leukocytes. In: Rose NR, Friedman H, Fahey JL, eds. Manual of Clinical Laboratory Immunology. 3rd ed. Washington, DC: American Society for Microbiology; 1986:226-235.

  15. Kikutani H, Inui S, Sato R, et al. Molecular structure of human lymphocyte receptor for immunoglobulin E. Cell. 1986;47:657-665.

  16. Kilo MN, Dorfman DM. The utility of flow cytometric immunophenotypic analysis in the distinction of small lymphocytic lymphoma/chronic lymphocytic leukemia from mantle cell lymphoma. Am J Clin Pathol. 1996;105:451-457.

  17. Kintner C, Sugden B. Identification of antigenic determinants unique to the surfaces of cells transformed by Epstein-Barr Virus. Nature. 1981;294:458-460.

  18. Loken MR, Shah VO, Dattilio KL, Civin CI. Flow cytometric analysis of human bone marrow. II. Normal B-lymphocyte development. Blood. 1987;70:1316-1324.

  19. Marti GE, Zenger V, Caproaso NE, et al. Antigenic expression of B-cell chronic lymphocytic leukemic lymphocytes. Anal Quant Cytol Histol. 1989;11:315-323.

  20. Matutes E, Morilla R, Owusu-Ankomah K, Houliham A, Meeus P, Catovsky D. The immunophenotype of hairy cell leukemia (HCL). Proposal for a scoring system to distinguish HCL from B-cell disorders with hairy or villous lymphocytes. Leuk Lymphoma. 1994;14:57-61.

  21. Matutes E, Owusu-Ankomah K, Morilla R, et al. The immunological profile of B-cell disorders and proposal of a scoring system for the diagnosis of CLL. Leukemia. 1994;8(10):1640-1645.

  22. Moldenhauer G, Dörken B, Schwartz R, Pezzutto A, Knops J, Hammerling GJ. Analysis of ten B lymphocyte-specific workshop monoclonal antibodies. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, eds. Leukocyte Typing II: Human B Lymphocytes. New York, NY: Springer-Verlag; 1986;2:61-67.

  23. Nadler LM. B Cell/Leukemia Panel Workshop: summary and comments. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, eds. Leukocyte Typing II: Human B Lymphocytes. 1986;2:3-43.

  24. Nadler LM. Cluster report: CD23. In: Reinherz EL, Haynes BF, Nadler LM, Bernstein ID, eds. Leukocyte Typing II: Human B Lymphocytes. 1986;2:25-26.

  25. Reichert T, DeBruyère M, Deneys V, et al. Lymphocyte subset reference ranges in adult Caucasians. Clin Immunol Immunopath. 1991;60:190-208.

  26. Rothe G, Schmitz G. Consensus protocol for the flow cytometric immunophenotyping of hematopoietic malignancies. Leukemia. 1996;10:877-895.

  27. Stelzer GT, Marti G, Hurley A, McCoy P, Jr., Lovett EJ, Schwartz A. US-Canadian consensus recommendations on the immunophenotypic analysis of hematologic neoplasia by flow cytometry: standardization and validation of laboratory procedures. Cytometry. 1997;30:214-230.

  28. Tedder T, Zhou L-J, Engel P. The CD19/CD21 signal transduction complex of B lymphocytes. Immunol Today. 1994;15:437-442.

  29. Thorley-Lawson D, Nadler L, Bhan A, Schooley R. Blast-2 (EBVCS), an early cell surface marker of human B cell activation, is superinduced by Epstein Barr Virus. J Immunol. 1985;134:3007-3012.

  30. Tworek JA, Singleton TP, Schnitzer B, Hsi ED, Ross CW. Flow cytometric and immunohistochemical analysis of small lymphocytic lymphoma, mantle cell lymphoma, and plasmacytoid small lymphocytic lymphoma. Am J Clin Pathol. 1998;110:582-589.

  31. Yukawa K, Kikutani H, Owaki H, et al. A B-cell– specific differentiation antigen, CD23, is a receptor for IgE (FcεR) on lymphocytes. J Immunol. 1987;138:2576-2580.

  32. Zola H, Neoh SH, Potter A, Melo JV, De Oliveria MSP, Catovsky D. Markers of differentiated B cell leukaemia: CD22 antibodies and FMC7 react with different molecules. Disease Markers. 1987;5:227-235.

品牌介绍
BD是世界上最大的生产和销售医疗设备、医疗系统和试剂的医疗技术公司之一。致力于提高全世界人类的健康水平。BD专注于改进药物治疗,提高传染性疾病诊断的质量和速度,推进新型药物和疫苗的研究与发现。BD公司具有强大的研发能力和世界上最棘手的多种疾病进行斗争的能力。公司于1897年在纽约成立,总部位于美国新泽西州的富兰克林湖,业务遍及全球。公司的业务可分为BD医疗、BD诊断、BD生物科学三大类,生产销售包括医用耗材、实验室仪器、抗体、试剂、诊断等产品。公司的服务对象包括医疗机构,生命科学研究所,临床实验室,工业单位和普通大众。BD has state-of-the-art facilities around the globe that provide an environment that enables our highly talented workforce to be the best at their professions. We hire associates who have a passion and commitment to advancing the world of health. We are always seeking great people to join our company on its journey to greatness.BDRat Granulocytes Pure RP-1  500ug550002BDMs Ig Kpa Lgt Chain FITC 187.1  500ug550007BDICC Fixation Buffer 100mL550011BDMs CD210 NALE 1B1.3a 500ug550019BDMs CD51 Pure RMV-7 100ug550026BDMs CD5 APC 53-7.3 100ug550037BDHu CD62E PE-Cy5 68-5H11 100Tst550041BDHu CD95 Pure EOS9.1  100ug550052BDHam IgG2 Kpa ItCl FITC B81-3 250ug550057BDMs Crry/p65 Pure 1F2 100ug550059BDMs IL-4 Recom Protein 10ug550068BDMs IL-2 Recom Protein 20ug550070BDHu IL-6 Recom Protein 10ug550072BDHu MIP-1 Bta PE D21-1351 100ug550082BDMs IgG1 PE A85-1 100ug550084BDHam IgG2 Kpa ItCl PE B81-3 100ug550086BDHu CD142 Pure HTF-1 100ug550254BDHu CD1d PE CD1d42 100Tst550256BDHu CD73 PE AD2 100Tst550258BDHu CD103 FITC Ber-ACT8 100Tst550260BDMs CD11c APC HL3 100ug550268BDMs CD72b/c Aloatg PE JY/93 100ug550270BDRat CD32 Pure D34-485 500ug550272BDRat CD32 NALE D34-485 500ug550274BDMs CD3e IHC Pure 145-2C11 1mL550277BDMs CD4 IHC Pure H129.19 1mL550280BDMs CD8a IHC Pure 53-6.7 1mL
联络我们
服务热线:4000-520-616
(限工作日9:00-18:00)
QQ :1570468124
手机:18915418616